TriClip™ TEER

INTENTIONALLY DESIGNED
FOR TRICUSPID SUCCESS1,2

THE TRICUSPID VALVE HAS FINALLY MET ITS MATCH

TriClip™ G4 TEER System.
Unmatched stability, precision, control.3*

* Based on Abbott simulated horizontal tensile testing.

Specifically Engineered
to Navigate the Right Heart Anatomy1,2

F/E Knob

S/L Knob

Steerable Guide Catheter

+/- Knob

Distal Curve

TriclipTM G4 Delivery System

Controlled Gripper Actuation

ACTUATOR KNOB

  • Flexes and extends delivery catheter to steer down to the valve plane

  • Enables movement in septal or lateral direction

  • Designed for the right side
    • Provides adequate height over the valve
    • Enables physicians to maintain coaxial position during steering and positioning
    • Allows sweeping away from the septum to optimize delivery catheter while maintaining perpendicularity to the plane of the valve
  • Straightens and curves guide for height adjustment above the valve

  • Designed for optimized access to the tricuspid valve

    • Provides stability and precision during steering and positioning
    • Multiaxis steering to enable navigation across all lines of coaptation
  • Confirm and Optimize Leaflet Grasping

  • Simultaneous implant and gripper detachment.

EPIC™ SUPRA AORTIC STENTED TISSUE VALVE FEATURES
1
2
3
4
5
6
7
8
    • Provides stability and precision during steering and positioning
    • Multiaxis steering to enable navigation across all lines of coaptation
  1. Flexes and extends delivery catheter to steer down to the valve plane
  2. Enables movement in septal or lateral direction
  3. Straightens and curves guide for height adjustment above the valve
  4. Designed for the right side

    • Provides adequate height over the valve
    • Enables physicians to maintain coaxial position during steering and positioning
    • Allows sweeping away from the septum to optimize delivery catheter while maintaining perpendicularity to the plane of the valve
  5. Designed for optimized access to the tricuspid valve
  6. Confirm and Optimize Leaflet Grasping
  7. Simultaneous implant and gripper detachment.

BUILDING ON A LEGACY OF UNMATCHED TEER EXPERTISE4

TriClip™ Implants use the same proven leaflet technology as our MitraClip™ Transcatheter Edge-to-Edge Repair (TEER). TriClip TEER is the clip-based technology physicians know and trust, with a delivery system uniquely designed for the tricuspid valve.

TriClip™ IMPLANT FEATURES

  • Cobalt-chromium and Nitinol construction
  • Polyester cover designed to promote tissue growth
  • Magnetic resonance conditional to 3 Tesla

† Static magnetic field up to 3 T; maximum spatial gradient in static field of 4000 gauss/cm or less; maximum whole-body averaged specific absorption rate (SAR) of 2 W/kg for 15 minutes of scanning.

BROAD RANGE OF SIZES FOR TAILORED TREATMENT

4 implant sizes for patient-specific therapy with the TriClip G4 TEER System5

Optimized leaflet capture for consistent TR reduction with the TriClip G4 TEER System

  • Wide grasp opening allows full leaflet insertion5
  • Designed to distribute retention forced across the leaflets7,8
  • Controlled gripper actuation enables independent leaflet grasping and confirmation, when needed5

MAT-2006555 v3.0 | Item approved for Global OUS use only.

References
  1. Data on file at Abbott. PS2203200
  2. Data on file at Abbott. PS2203401
  3. Testing performed by and data on file at Abbott. RPT2133700
  4. Data on file at Abbott. Market Research 2021
  5. Data on file at Abbott. PS2203400
  6. Testing performed by and data on file at Abbott. RPT2204519-01R
  7. Testing performed by and data on file at Abbott. RPT2122822-R
  8. Testing performed by and data on file at Abbott. RPT2124838-R

Sign up

Receive updates from Abbott Structural Heart

YOU ARE ABOUT TO ENTER AN ABBOTT COUNTRY OR REGION SPECIFIC WEBSITE.

Please be aware that the website you have requested is intended for the residents of a particular country or countries, as noted on that site. As a result, the site may contain information on pharmaceuticals, medical devices and other products or uses of the product that are not approved in other countries or regions.

YOU ARE ABOUT TO LEAVE
www.structural­heart­solutions.com

You are now leaving www.structuralheartsolutions.com. Abbott is not responsible for any content published on the third-party website you are about to enter. Abbott has not reviewed and does not endorse any information presented on third-party websites.